Issafrica is a leading Liquid Chromatography Digital System Manufacturer,and suppliers in Africa, Liquid Chromatography Digital System Manufacturer,and suppliers in South Africa, Liquid Chromatography Digital System Algeria (Algiers), Liquid Chromatography Digital System Angola (Luanda), Liquid Chromatography Digital System Argentina (Buenos Aires), Liquid Chromatography Digital System Armenia (Yerevan), Liquid Chromatography Digital System Australia (Canberra), Liquid Chromatography Digital System Austria (Vienna), Bahrain (Manama), Bangladesh (Dhaka), Bhutan (Thimphu), Bolivia (Sucre), Botswana (Gaborone), Brazil (Brasília), Brunei (Bandar Seri Begawan), Montenegro (Podgorica), Morocco (Rabat), Mozambique (Maputo), Myanmar (Naypyidaw), Namibia (Windhoek), Nepal (Kathmandu), New Zealand (Wellington), Nigeria (Abuja), Oman (Muscat), Palestine (Ramallah), Panama (Panama City), Papua New Guinea (Port Moresby), Paraguay (Asunción), Peru (Lima), Philippines (Manila)¸ Portugal (Lisbon), Qatar (Doha), Rwanda (Kigali), Saudi Arabia (Riyadh), Senegal (Dakar), Serbia (Belgrade), Sierra Leone (Freetown), Slovakia (Bratislava), South Africa (Cape Town) (Pretoria) (Bloemfontein), South Sudan (Juba), Spain (Madrid), Sri Lanka (Sri Jayawardenepura Kotte) (Colombo), Sudan (Khartoum), Syria (Damascus), Tanzania (Dodoma), Thailand (Bangkok), Togo (Lomé), Tonga (Nuku'alofa), Trinidad and Tobago (Port of Spain), Tunisia (Tunis), Turkey (Ankara), Turkmenistan (Ashgabat), Uganda (Kampala), United Arab Emirates (Abu Dhabi), United Kingdom (London), United States (Washington, D.C.).

Liquid Chromatography Digital System
Specification:- 
 
HPLC:-
Ultra speed data processing by Network HPLC.
Designed for all you need in the lab. 
Versatile dedicated applications.
Accurate and reliable data.
Stylish and compact design.
Enhanced superior performance.

Quaternary Pump:-
Gradient formation: 4-channel mixing valve.
Composition Precision: < 0.1%.
Composition Accuracy: < 0.5%.
Operating principle: Parallel dual-plunger pump, Low-pressure gradient.
Number of Solvents: up to 4 solvents.

Binary Pump:-
Configure with Gradient pump. 
Operating principle: Double parallel dual-plunger pump,
High-pressure gradient.

Vacuum Degasser:-
Number of channel: 4 channels.
Maximum flow rate: 10ml/min per channel 0~2.0ml/min per channel for 70% Gas Removed from Methanol.
Internal volume per channel: 925 ul per channel.
Materials in contact with the solvent.
Teflon AF, PEEK, and Glass-filled PTEE.

Column Compartment:-
Temperature stability: ± 0.05°C
Temperature range: 4°C (Cooling) - 90°C
Column capacity: Max. 3 ea of 30 cm column (Analytical)
Max. 2 ea of 30 cm column (Semi-Prep)
Temperature accuracy: ±0.5°C 

UV/Vis Detector:-
Drift: < 1 × 10-4 AU/hr 
Wavelength Range: 190~900nm (Dual wavelength)
Data collection rate: up to 50Hz
Noise level: < ±0.5 × 10-5 AU, 254nm, dry cell
Linearity: > 99.5% for 2.5AU (acetone, 254nm)

PDA Detector:-
No. of PDA Channel: 1024
Wavelength: 190 ~ 950nm
Noise Level: 2 × 10-5 AU (Empty Cell, 1 sec Rise Time, 254nm)
Drift: 2 × 10-4 AU/hr (Baseline Correction), 0.001AU/hr (Room Temp)
Wavelength Accuracy: 1nm (HY-1 Holmium Oxide Filter)

RI Detector:-
RI Range: 1.00~1.75 RIU
Flow Cell Volume: 9 ul (Analytical) / 7 ul (Semi-prep)
Noise: ≤ 5 × 10-9 RIU (Analytical) / ≤ 10 × 10-8 RIU (Semi-prep) 

   